806f020d-040cffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 12)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d040cffff or 0x806f020d040cffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix:
PLAT
ID:
0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
•
806f020d-040dffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 13)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d040dffff or 0x806f020d040dffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
434
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Summary of Contents for HX1310
Page 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Page 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 1001: ......
Page 1002: ......