![Larsen & Toubro C*2000 Series User Manual Download Page 56](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507056.webp)
Chapter 5 – Parameter list
5-11
Cx2000 AC Drive
F68
3)
1244
400V input
voltage
320
~
480[V]
400V inverter input voltage set
380
0
8-30
1)
: It is indicated when setting bit 2 of F59 as 1
2)
: Set F63 to 1 to display this parameter.
3)
: 200V inverter displays F67, 400V inverter displays F68.
Function group 1
LED
display
Address
for
comm
Parameter
name
Range
Description
Factory
defaults
Adj.
During
run
Page
F70
1246
Draw run
mode select
0
~
3
0
Inverter doesn‟t run as a draw mode
0
X
8-27
1
Analog terminal AI V terminal (0-10 V)
input drawn run
2
Analog terminal AIV terminal (0-20 V)
input drawn run
3
Panel potentiometer V2 (0-5V) input
draw run
F71
1247
Draw rate
0
~
100[%]
Set rate of draw
0.0
O
8-27
F72
2)
1248
ND/HD
selection
0
~
1
0: HD (CT) heavy load
1: ND (VT) light load
0
X
8-22
F73
1)
1249
200V DB
start voltage
300
~
400[V]
Set DB start voltage of 200V class inverter
390
0
8-32
F74
1)
124A
400V DB
start voltage
600
~
800[V]
Set DB start voltage of 400V class inverter
780
0
8-32
1)
: 200V inverter displays F73, 400V inverter displays F74.
2)
:
only HD selection for single phase 200V inverter
Function group 2
LED
display
Address
for
comm
Parameter
name
Range
Description
Factory
defaults
Adj.
During
run
Page
H 0
1300
Jump code
0
~
95 Sets the code number to jump.
1
O
4-5
H 1
1301
Fault history 1
-
Stores information on the types of faults,
the frequency, the current and the
Accel/Decel condition at the time of fault.
The latest fault is automatically stored in
nOn
-
9-4
H 2
1302
Fault history 2
-
nOn
-
H 3
1303
Fault history 3
-
nOn
-
H 4
1304
Fault history 4
-
nOn
-
Summary of Contents for C*2000 Series
Page 163: ......