Chapter 8 Application
8-3
Cx2000 AC Drive
8.2 Jog control
Jog Operation
Group
Code
Item
Set Value Setting Range Initial Unit
Function Group 1
F20
Jog frequency
-
0.00~ 400.00
10.00 Hz
I/O Group
I21
Multi-function input terminal
P5 function selection
4
0 ~ 27
4
Function group 1: set the jog frequency in F20.
Select a terminal to use for jog operation from multi-function input terminals (P1~P8)
If P5 is set for jog operation, set I21 to 4 (jog)
Jog frequency can be set within the range of F21 [Max frequency] and F23 [Start frequency].
Jog operation overrides all other operations except Dwell operation. Therefore, if Jog frequency
command is entered in the middle of Multi-Step, Up-Down or 3-wire operation, operation is executed at
Jog frequency.
JOG FX/RX Operation
Group
Code
Item
Set Value Setting Range Initial Unit
Function Group 1 F20
Jog frequency
-
0.00~ 400.00
10.00 Hz
I/O Group
I20
Multi-function input terminal
P4 function selection
26
0 ~ 27
3
I21
Multi-function input terminal
P5 function selection
27
0 ~ 27
4
P 5 (JOG)
운 전 지 령 (FX )
주 파 수
F20
P 1
P 5
C M
F X : I17 = 0
JO G : I21= 4
Run Command
Frequency
P5 (JOG)
전 압
운 전 지 령
F12
P 3
Voltage
P3
Run command
Summary of Contents for C*2000 Series