![Larsen & Toubro C*2000 Series User Manual Download Page 22](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507022.webp)
Chapter 2 INSTALLATION & WIRING
2-8
Cx2000 AC Drive
2.4 Specifications for power terminal block wiring
R
T
P1
P2
N
B
U
V
W
R
T
B
P1
P2
N
U
V
W
P1
P2
N
R
T
B
U
V
W
R
S
T
P1
P2
N
B
U
V
W
R
S
T
B
P1
P2
N
U
V
W
P1
P2
N
R
S
T
B
U
V
W
R
S
T
P1
P2
B
N
U
V
W
0. 1KW
- 0. 4KW
( si ngl e phase 200V)
0. 75KW
- 1. 5KW
( si ngl e phase 200V)
2. 2KW
( si ngl e phase 200V)
0. 1KW
- 0. 75KW
( t hr ee phase 400V)
1. 5KW
- 2. 2KW
( t hr ee phase 200V/ 400V)
3. 7kW
( t hr ee phase 200V/ 400V)
5. 5KW
- 7. 5KW
( t hr ee phase 200V/ 400V)
R,S,T Size
U,V,W Size
Ground Size
Terminal
Screw Size
Screw Torque
(Kgf.cm)/lb-in
mm
2
AWG mm
2
AWG
mm
2
AWG
LTVF-C10001BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C10002BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C10003BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C10005BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C10008BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C10011BAA
3.5
12
3.5
12
3.5
12
M4
12.2/10.6
LTVF-C20001BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20002BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20003BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20006BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20010BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20012BAA
2
14
2
14
3.5
12
M3.5
10/8.7
LTVF-C20018BAA
3.5
12
3.5
12
3.5
12
M4
12.2/10.6
LTVF-C20030BAA
6
10
6
10
5.5
10
M4
15/13
LTVF-C20040BAA
6
10
6
10
5.5
10
M4
15/13
LTVF-C40002BAA
2
14
2
14
2
14
M3.5
10/8.7
LTVF-C40003BAA
2
14
2
14
2
14
M3.5
10/8.7
LTVF-C40005BAA
2
14
2
14
2
14
M3.5
10/8.7
LTVF-C40007BAA
2
14
2
14
2
14
M3.5
10/8.7
LTVF-C40010BAA
3.5
12
3.5
12
2
14
M4
12.2/10.6
LTVF-C40016BAA
3.5
12
3.5
12
3.5
12
M4
13.8/12
LTVF-C40023BAA
3.5
12
3.5
12
3.5
12
M4
13.8/12
Strip the sheaths of the wire insulation 7.0mm when a ring terminal is not used for power connection.
77.0mm
Summary of Contents for C*2000 Series