Chapter 12 Troubleshoot and maintenance
12-6
Cx2000 AC Drive
Electronic thermal
protection
Motor is overheated.
The inverter load is greater than the
rated value.
The electric thermal protection is set
too low.
The inverter capacity is set
incorrectly.
Long operation at low speed.
Reduce the load or running
frequency.
Increase the inverter capacity.
The electronic thermal protection
rating is set correctly.
Set the inverter capacity correctly.
Choose a cool fan with a
separate power supply.
Fault remedy
Protective functions
Abnormal causes
Countermeasures
Contract A
Fault signal input
The terminal with the function c
hoice (117
~
121)of multi-function in
put terminal set with 18 is closed.
The terminal with the function c
hoice (117
~
121)of multi-function in
put terminal set with 19 is opened.
Remove the abnormity of the loop
connected on the external fault terminal
and check the causes for external faults.
Contract B
Fault signal input
Frequency
command loss
Inverter terminal V1 and I has
no frequency commands.
Check the connection wiring of AIN
terminal and command grade.
Brake control
Abnormity
Operation is not available if
there is no brake open current.
Check the capacity and wiring of
motor.
EEP: Parameter save error
HWT: Hardware fault
iE7: Communication error between panel and inverter.
COM: Keypad error
NTC: NTC error
Contact your local LT Branch.