![Larsen & Toubro C*2000 Series User Manual Download Page 47](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507047.webp)
Chapter 5 – Function list
5-2
Cx2000 AC Drive
7
RS-485 communication
7-5
8
Digital (UP/DOWN) rotation
8-4
Drive Group
LED
display
Address
for
comm
Parameter
name
Set
range
Description
Factory
defaults
Adj.
during
run
Page
St1
1105
Multi-step
frequency
1
0.00
~
400.00
[Hz]
Sets Multi-step frequency 1 during Multi-
step operation
0.00
O
7-7
St2
1106
Multi-step
frequency
2
Sets multi-step frequency 2 during multi-
step operation
0.00
O
7-7
St3
1107
Multi-step
frequency
3
Sets multi-step frequency 3 during multi-
step operation
0.00
O
7-7
CUr
1108
Output
current
[A]
Displays the output current to the motor.
-
-
9-1
rPM
1109
Motor
RPM
[rPM]
Displays the number of Motor RPM.
-
-
9-1
dCL
110A
DC link
voltage
[V]
Displays DC link voltage inside the
inverter
-
-
9-1
vOL
110B
User
display
select
-
This parameter displays the item
selected at H73- [Monitoring item
select].
vOL
-
9-2
vOL
Output voltage
POr
Output power
tOr
Torque
nOn
110C
Fault
Display
-
Displays the types of faults, frequency
and
operating status at the time of the fault
-
-
9-4
drC
110D
Direction
of motor
rotation
F, r
Direction of motor rotation when drv
(Drive mode) is set to 0.
F
O
7-8
F Forward
r Reverse
drv2
1)
110E
Drive
mode 2
0
~
0
Run/Stop via Run/stop key on the
keypad
1
X
8-22