Chapter 4 Parameter setting
4-6
Cx2000 AC Drive
Navigating codes in the same parameter group
When moving from F 1 to F 15 in Function group 1
1
-. F1 of Function parameter group 1 is
displayed,
-. Continue pressing the Up (
) key until F28
is displayed.
2
-. F28 of Function parameter group 1 is
displayed.
The same applies to Function group 2 and I/O group.
Some codes will be skipped when the Up(
) or Down (
) is used, that is because the codes
have not been activated due to no use, or some codes intentionally left blank for future use. Refer
to the Ch.5 for more specific contents
For example, when F24 [High/low frequency limit select] is set to “O (No) ”, F25 [High frequency
limit] and F26 [Low frequency limit] are not displayed during code change. But When F24 is set to
“1(Yes)”, F25 and F26 will appear on the display.