Section 7: TSP command reference
Series 2600B System SourceMeter® Instrument Reference Manual
7-260
2600BS-901-01 Rev. B / May 2013
Bit
Value
Description
B0
Not used
Not applicable.
B1
status.measurement.current_limit.SMUA
Set bit indicates that the SMU A current limit
was exceeded.
Bit B1 decimal value: 2
Binary value: 0000 0010
B2
status.measurement.current_limit.SMUB
This bit is only available on Models
2602B/2604B/2612B/2614B/2634B/2636B. Set
bit indicates that the SMU B current limit was
exceeded.
Bit B2 decimal value: 4
Binary value: 0000 0100
B3-B15
Not used
Not applicable.
As an example, to set bit B1 of the measurement event current limit summary enable register, set
status.measurement.current_limit.enable = status.measurement.current_limit.SMUA
.
In addition to the above constants,
measurementRegister
can be set to the decimal equivalent of the bit to
set. To set more than one bit of the register, set
measurementRegister
to the sum of their decimal weights.
For example, to set bits B1 and B2, set
measurementRegister
to 6 (which is the sum of 2 + 4).
Example
status.measurement.current_limit.enable =
status.measurement.current_limit.SMUA
Sets the SMUA bit of the
Measurement Event Current Limit
Summary Enable Register.
Also see
Measurement event registers
(on page E-8)
status.measurement.instrument.smuX.*
(on page 7-262)
status.measurement.instrument.*
This attribute contains the registers of the measurement event instrument summary register set.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Attribute
- -
- -
- -
- -
.condition (R)
Yes
Not applicable
Not saved
Not applicable
.enable (RW)
Yes
Status reset
Not saved
0
.event (R)
Yes
Status reset
Not saved
0
.ntr (RW)
Yes
Status reset
Not saved
0
.ptr (RW)
Yes
Status reset
Not saved
Models 2601B/2611B/2635B: 2 (All bits set)
Models
2602B/2604B/2612B/2614B/2634B/2636B:
6 (All bits set)
Usage
measurementRegister
= status.measurement.instrument.condition
measurementRegister
= status.measurement.instrument.enable
measurementRegister
= status.measurement.instrument.event
measurementRegister
= status.measurement.instrument.ntr
measurementRegister
= status.measurement.instrument.ptr
status.measurement.instrument.enable =
measurementRegister
status.measurement.instrument.ntr =
measurementRegister
status.measurement.instrument.ptr =
measurementRegister
Summary of Contents for System SourceMeter 2601B
Page 841: ......