Series 2600B System SourceMeter® Instrument Reference Manual
Section 2: General operation
2600BS-901-01 Rev. B / May 2013
2-23
To edit compliance limit values:
1. Press the
LIMIT
key.
2. Use the
CURSOR
keys (or turn the navigation wheel
) to move the cursor to the digit that
needs to be changed.
3. Press the navigation wheel
or the
ENTER
key to enter edit mode. The EDIT indicator is
illuminated.
4. Change the compliance value (see
Setting values
(on page 2-21)).
5. When finished, press the
ENTER
key (the EDIT indicator is not illuminated).
The up and down range keys change the format of the limit value.
Beeper
The Series 2600B includes a beeper. When it is enabled, a beep indicates one of the following
actions have occurred:
•
A front-panel key was pressed: A short beep, similar to a key click, is issued.
•
The navigation wheel
was turned or pressed: A short beep is issued.
•
The output source was changed: A longer beep is issued when you press the OUTPUT ON/OFF
control (turn the output on or off).
To turn the beeper on or off from the front panel:
1. Press the
MENU
key, and then select
BEEPER
.
2. Select one of the following:
•
ENABLE
•
DISABLE
To turn the beeper on or off from the TSP command interface:
Set the
beeper.enable
attribute. For example, to enable the beeper, send:
beeper.enable = 1