Section 2: General operation
Series 2600B System SourceMeter® Instrument Reference Manual
2-18
2600BS-901-01 Rev. B / May 2013
The following table contains descriptions of the main menu options and cross-references to related
information. To access a menu option, press the
MENU
key, turn the navigation wheel
to move the
cursor to select an item, and press the navigation wheel
.
Menu selection
Description
For more information, see:
SCRIPT
Saves and recalls users scripts
Manage scripts
(on page 6-3)
- LOAD
Loads scripts into nonvolatile memory
- SAVE
Saves scripts
SETUP
Saves and recalls user and factory setup options
Saved setups
(on page 2-46)
- SAVE
Saves user setup options
- RECALL
Recalls user setup options
- POWERON
Sets the configuration used during startup
GPIB
Configures the GPIB interface options
Remote communication interfaces
(on
- ADDRESS
Configures the address for the GPIB interface
- ENABLE
Enables and disables the GPIB interface
LAN
Configures the local area network (LAN)
LAN concepts and settings
(on page C-1)
- STATUS
Displays LAN connection status
- CONFIG
Configures the LAN IP address and gateway
- APPLY_SETTINGS
Applies changes made using the CONFIG menu
- RESET
Restores the default settings
- ENABLE
Enables and disables the LAN interface
RS232
Controls the options for the RS-232 interface
Remote communication interfaces
(on
- BAUD
Sets the baud rate
- BITS
Configures the number of bits
- PARITY
Sets the parity
- FLOW-CTRL
Configures the flow control
- ENABLE
Enables and disables the RS-232 interface
TSPLINK
1
Configure the instrument in a TSP-Link
®
network
TSP-Link system expansion interface
(on
- NODE
Selects the instrument node identifier
- RESET
Resets the TSP-Link network
UPGRADE
Upgrades the firmware from a USB flash drive
Upgrading the firmware
DISPLAY
Accesses display functions
Front panel tests
- TEST
Runs the display test
See Numeric entry method in
Setting a
value
- NUMPAD
Enables and disables the numeric keypad
DIGOUT
2
Controls digital outputs
Digital I/O
- DIG-IO-OUTPUT
Selects the digital I/O values
- WRITE-PROTECT
Write-protects specific digital I/O lines
BEEPER
Controls the key beeps
General operation
- ENABLE
Enables the key beeps
- DISABLE
Disables the key beeps
LINE-FREQ
Configures the line frequency
General operation
- 50Hz
Set the line frequency to 50 Hz
- 60Hz
Set the line frequency to 60 Hz
- AUTO
Enables automatic line frequency detection during
start up
SYSTEM-INFO
Displays the system information
General operation
- FIRMWARE
Displays the version of firmware installed
- SERIAL#
Displays the serial number of the unit
- CAL
Displays the last calibration date
- MEMORY-USAGE
Displays memory usage in percentage
RESET-PASSWORD
Resets the system password
Password management
1. TSPLINK is not available on the Models 2604B, 2614B, and 2634B.
2. DIGOUT is not available on the Models 2604B, 2614B, and 2634B.