Load management program
50 / 156
Power profile
Valid from:
Point in time at which the validity of a Power Profile begins. A Power Pro-
file remains valid until its successor gets valid.
[DD.MM.YYYY]
Special day:
Special day(s) at which the Power Profile overrides the currently active
Power Profile.
Reserved for ISO 15118:
[Only in combined mode ac-
tive]
Percentage of the Maximum Current Offered that is reserved for Electric
Vehicles using high-level communication.
[Maximum is 100%]
100% means that the complete available power of the M10 is reserved for
ISO 15118 vehicles, even if Mode 3 vehicles want to charge.
Power profile items
Item name:
Name of the Power Profile.
Days of week:
Days of the week at which the Power Profile is valid.
(Monday, Tuesday, Wednesday,….)
From / To:
Time period from / to the Power Profile is valid.
Max. Current [A]:
Maximum current for this Power Profile.
Price:
Energy price during this Power Profile.
Current 15118 [A]:
Current (in Ampere) that is reserved for charging by vehicles using high-
level communication.
Optional: If no value is set, the value will be calculated as follows:
“Reserved for ISO 15118” x “Max current” / 100