Load management program
140 / 156
Central System interfaces
Name:
Name of the interface.
Type:
Type of the interface.
Display values:
System Management
The interface is used for monitoring, managing and configuring the
KeContact server.
Energy Management
The interface is used to manage the energy offered by the charge
point. An example is a DSO interface using OCPP.
Energy and System Management
The interface is used for system management and energy manage-
ment.
Status:
Status of the interface.
Display values:
Online
The KeContact server is communicating with the central system using
the OCPP interface.
Offline
The host interface is working, but the central system is currently not
reachable.
Stopped
The interface to the central system has been temporarily deactivated.
Status Time:
Time of the status change.
Buttons
Start:
Press the [Start] button, to start a stopped host interface.
Stop:
Press the [Stop] button, to stop the selected host interface.
Delete:
Press the [Delete] button, to delete the selected host interface.
Any message that has not been sent will be purged. The system might
automatically restart to complete the deletion.
Change:
Press the [Change] button, to change the parameters of the selected
host interface.
Create:
Press the [Create] button, to enter parameters for a new host interface.
Additional information:
OCPP (“Open Charge Point Protocol”) is an interface between the KeContact M10 and an OCPP host. In-
formation about the status, meter values, errors of the M10 and the connected Wallboxes will be provided if