Hardware installation
19 / 156
4.4 Wallbox numbering and Ethernet addressing
Wallbox numbering (1 to 15):
The unique address that is selected with the DIP switches inside the Wallbox is also the unique number (1 to
15) of the Wallbox that is used in the Load management program.
►
Please place a sticker with the selected number clearly visible on the housing of the Wallbox to
make it easier to identify the Wallbox in the Load management program.
The IP addresses on the closed KeContact LAN shall be determined as follows:
IP range: 192.168.25.xx
xx
…
Unique address (= Wallbox number / Network Membership ID) of the KeContact P20 Wallbox.
Note: The settable Ethernet addresses start at
10 + DIP switch setting
.
DIP switches
DIP switches Wallbox
The address of the Wallbox is set with DIP switches
inside the Wallbox (for details please see chapter "DIP-
switch settings" and the “KeContact P20 Installation
manual”).
KeContact M10 display
Showing the IP address
For information purpose the current IP address of the
KeContact M10 can be seen on its display.
Connecting to a Public LAN (corporate network)
If you want to use the Public LAN connection (Eth1) of the KeContact M10, it is required to get an IP address
from your corporate DHCP server.
Please ask your network administrator for the detailed integration of the KeContact M10 in your corporate
network. This is not part of this manual.