Load management program
88 / 156
Reserved for ISO 15118:
[Only in combined mode ac-
tive]
Percentage of the Maximum Current Offered that is reserved for Electric
Vehicles using high-level communication.
[Maximum is 100%]
100% means that the complete available power of the M10 is reserved for
ISO 15118 vehicles, even if Mode 3 vehicles want to charge.
Maximum current Charge
Point:
Max available current (in Ampere) that is available at the Charge Point.
Most likely, this is a limitation determined by the power delivery contract
of the organization.
Power profile items
Power profile item name:
Name of the Power Profile for presentation purposes.
The dropdown box contains all values contained in the database and a
value to indicate "new". If "New power profile item name" is selected, a
screen with an empty item will be presented to enter a new Power Profile
item name.
Power profile entries
Item name:
Name of the Power Profile Item.
Days of week:
Days of the week at which the Power Profile is valid.
(Monday, Tuesday, Wednesday,….)
From / To:
Time period from / to the Power Profile is valid. The “Valid from” date
must be in the future and may not be identical to the “Valid from” date of
other Power Profiles.
Max. Current [A]:
Maximum current for this Power Profile. This value may not exceed the
Maximum Current of the Charge Point.
Price:
Energy price during this Power Profile. The price may not be negative.
Current 15118 [A]:
Current (in Ampere) that is reserved for charging by vehicles using high-
level communication. This value may not exceed the Maximum Current of
the Charge Point.
Optional: If no value is set, the value will be calculated as follows:
“Reserved for ISO 15118” x “Max current” / 100
Buttons
Save:
Press the [Save] button to save the Power Profile settings.
Additional information:
You are able to edit a Power Profile only if the Power Profile was not active in the past or is not currently
active.
Summary of Contents for KeContact Series
Page 1: ...KeContact Load Management System manual...
Page 151: ...Appendix 151 156 7 3 Data sheet power supply TDK Lambda DPP50 Dimensions...
Page 152: ...Appendix 152 156...
Page 156: ......