Load management program
52 / 156
Session state:
Shows the state of the current Charging Session.
Display values:
Not plugged in:
No electric vehicle is connected to the Wallbox.
Standby:
The vehicle is connected, but on standby.
Charging:
The vehicle is charging or in a charging pause and the vehicle is not
blocked.
Blocked:
The vehicle has been blocked by the Wallbox or no active charging
transaction exists.
Error:
The socket is degraded or fatal.
Session start time:
Point in time when the Charging Session has started.
Departure Time:
Planned end of charging as communicated by the Electric Vehicle during
charge parameter discovery.
Charging State details
Signalling:
Describes whether the Charging Session is a Mode 3 charging session or
a high-level charging session.
Display values:
Basic signalling:
Mode 3 charging according to IEC 61851-1 controlled by basic signal-
ling.
ISO 15118:
Charging session controlled by high-level communication.
Number of phases:
The maximum number of phases which a Electric Vehicle can use during
the charging transaction. Must be 1 or 3.
Current offered:
Current offered at the Wallbox (taken from charging profile or the preas-
signed current, whichever applies).
Current measured:
Current according to the last measurement at the Wallbox.
Charging State details
Energy Requested:
Energy requested by the electric vehicle during the last charge parameter
negotiation. Empty for charging controlled by basic signalling.
Energy Consumed:
Energy consumed during the Charging Session.
Wallbox state:
Shows the state of the selected Wallbox.
Display values:
Free:
No vehicle is connected.
Not ready to charge:
The Wallbox is operational and the power switch is open.
Offering energy: