Load management program
85 / 156
A
power profile
can be entered at the GUI of the KeContact M10 that contains further limits that depend on
the time of day and the type of day. Those limits can be used to ensure that electric vehicles are charged at
a point in time when energy is less expensive or to reserve certain periods of the day for other energy con-
sumers. If no power profile is entered at the GUI, a default power profile is used that always offers the maxi-
mum available current.
The following picture shows an example power profile:
A
power profile
consists of one or more
power profile items
that apply to one or more days of week.
Every
power profile item
consist of one or more
power profile entries
giving the maximum current availa-
ble at a particular time interval.
A power profile is valid until the start of validity of a new power profile. A Power Profile only expires if there is
another Power Profile which becomes active in the future. Active or expired power profiles may not be
changed. A power profile may only be valid for a
special day
such as Easter Monday. After the end of the
special day, the previously active power profile will be reactivated again.