Load management program
64 / 156
Session
Session ID:
Unique identifier of the Charging Session.
Wallbox number:
Socket number of the Wallbox.
Session start time:
Point in time when the Charging Session has started.
Session end time:
Point in time when the Charging Session has ended.
Session history table
History type:
The most important types of history entries.
Display values:
Start session
A Charging Session has started.
Resume session
A charging session has been resumed by the Electric Vehicle.
End session
A Charging Session has ended.
Start transaction
A Charging Transaction has started.
Waiting authorization
The Wallbox waits for authorization.
End transaction
A Charging Transaction has ended.
Power exceeded
The Electric Vehicle has drawn more power than assigned in the
Charging Profile.
No ventilation
The Electric Vehicle has requested ventilation, but the socket doesn't
support ventilation.
Time:
Timestamp of the entry into the session history.
Meter reading:
Meter reading in the transaction history. Might be different from attributes
depending on the type of transaction.
Termination:
Termination reason at the session history. Might be either “Termination
Reasons Session” or “Termination Reason Transaction” depending on
the type of history entry.
Details:
Detailed information contained in the session history.
It will be populated with additional information such as "Contract ID" for
the start of a session or the measured current in case of exceeding the
assigned current.