Hardware installation
18 / 156
4.3 Ethernet wiring
For details about installing and connecting the components, please refer to the individual compo-
nent manuals (
KeContact P20 Installation manual
, Installation manual of your Ethernet switch
and patch panel).
Use the
LSA+® terminal block [ETH1]
for the Ethernet connection and NOT the RJ45 port.
In any case the KeContact LAN must be designed as a closed network without direct public access.
Only the KeContact M10 can be connected via the Ethernet port [ETH1] to a public LAN (eg, corporate
network).
The individual Wallboxes are wired to the patch panel using a Cat6 (or higher quality) patch cable.
The connection between Ethernet switch and patch panel is made with standard patch cables (2xRJ45).
Color coding:
According to the used wiring standard in the building, the contacts are wired according to
TIA-568A/B
for
100BaseT:
Pin
-568A
pair
-568B
pair
-568A
color
-568B
color
1 (Tx+)
3
2
white/green
white/orange
2 (Tx−)
3
2
green/white or green
orange/white or orange
3 (Rx+)
2
3
white/orange
white/green
4 (Rx−)
2
3
orange/white or orange
green/white or green
Ethernet port
Pin assignment of LSA+® terminal block [ETH1]
For det
ails please see the “KeContact P20 Installation
manual”.