background image

Biomass Controller SBMC

Installation and operating instructions

Read carefully before installation, commissioning and operation

1

Summary of Contents for SBMC

Page 1: ...Biomass Controller SBMC Installation and operating instructions Read carefully before installation commissioning and operation 1 ...

Page 2: ...r messages 12 Reset Clear 12 3 Display mode 12 Schematic 12 Overview 12 Alternating 12 Eco Display Mode 13 4 Operating mode 13 Automatic 13 Manual 13 Off 13 5 Settings 14 Tmin S1 14 Tmax S2 14 ΔT R1 14 Tmin Storage X 14 6 Protective Functions 15 Seizing Protection 15 Anti Legionella 15 7 Special Functions 16 Pump settings V1 Signal V1 16 Type of pump Type of signal 16 Pump Profile 16 Output Signal...

Page 3: ... prevention regulations VDE regulations the regulations of the local power utility the applicable DIN EN stand ards and the installation and operating instruction of the additional system components must also be observed Under no circumstances does the unit replace any safety devices to be provided by the customer Installation electrical connection commissioning and maintenance of the device may o...

Page 4: ...he entire system Warranty and Liability The Unit has been manufactured and tested with regard to high quality and safety requirements The warranty and liability shall not include however any injury to persons or material damage that is attributable to one or more of the following causes l Failure to observe these installation and operating instructions l Improper installation commissioning mainten...

Page 5: ...AC1 185 W for AC3 0 10V PWM output V1 for 10 k Ω working resistance 1 kHz level 10 V Max cable length Boiler sensor of this function S1 30 m Storage sensor S2 and S3 10 m 0 10V PWM 3m mechanical relay 10m Permissible Ambient Conditions for controller operation 0 C 40 C max 85 rel humidity at 25 C for transport storage 0 C 60 C no moisture condensation permitted Other Specifications and Dimensions ...

Page 6: ...entional setting changes l Resetting to previously selected values or factory settings Scope of supply l Biomass Controller l 2 screws 3 5 x 35 mm and 2 plugs 6 mm for wall installation l 4 strain relief clips with 8 screws replacement fuse 2TA l 1 connection clamp for PE terminal block l SBMC Installation and operating instructions Optionally contained depending on design order l Pt1000 temperatu...

Page 7: ...al conductor N R Pump outer conductor L N Pump neutral conductor N R Break contact The PE protective conductor must be connected to the PE metal ter minal block Terminal Connection for S1 2x Sensor 1 solid fuel boiler S2 2x Sensor 2 storage S3 2x Sensor 3 for display only The polarity of the sensors S1 S3 is freely selectable V1 0 10V PWM Pump 0 10V PWM Mass 7 ...

Page 8: ...tched on again Check that there is no power flowing Electrical connections may only be made by a specialist and in compliance with the applicable regulations The unit may not be put into operation if there is visible damage to the housing e g cracks The unit may not be accessible from behind Low voltage cables such as temperature sensor cables must be routed separately from mains voltage cables Fe...

Page 9: ...are accurate to 1 C ensuring optimal control of system func tions If desired the sensor cables can be extended to a maximum of 30 m using a cable with a cross section of at least 0 75 mm Ensure there is no contact resistance Position the sensor precisely in the area to be measured Only use immersion pipe mounted or flat mounted sensors suitable for the specific area of application with the appropr...

Page 10: ...on firmation appears to save the made changes The function of the other 3 keys 4 is shown in the display right above the keys The right hand key generally has a con firmation and selection function The graphics mode appears if no key is pressed for 2 minutes or after exiting the main menu with esc The temperature overview appears when you press the left button Tapping the button again leads back t...

Page 11: ...e consumers connected and check the sensor values for plausibility Then set to automatic mode see Manual on page 13 The setup wizard can be accessed in menu 7 6 at any time Consider the explanations for the individual parameters on the following pages and check if further settings are necessary for your application 1 Measurement values Serve to display the current measured temperatures If error ap...

Page 12: ...r illustration of the data as a bar graph Different time ranges are available for comparison You can page through with the two left keys Error messages Display of the last 15 errors in the system with indication of date and time Reset Clear Resetting and clearing the selected statistics Selecting all statistics clears everything except the error log 3 Display mode Used to define the controller s d...

Page 13: ...e last operating mode selected Manual In Manual mode the individual relay outputs and the connected consumers can be checked for proper functioning and correct assignment The operating mode Manual may only be used by specialists for brief function tests e g during commissioning Func tion in manual mode The relays and thus the connected consumers are switched on and off by pressing a key with no re...

Page 14: ...rature S2 is exceeded a downstream installed storage or storage area is switched to ΔT R1 On off temperature difference for solar charge through relay R1 If the temperature difference ΔT Solar between the reference sensors S1 and S2 is exceeded and the other conditions are ful filled the controller will turn on the pump on the relay R1 If the temperature difference falls to ΔT Off the pump will be...

Page 15: ...n with the date will be shown in the display This anti legionella function does not offer any secure protection against legionella because the controller requires an adequate added amount of energy and the temperatures cannot be monitored in the entire storage area and the con nected pipe system During the operation of the anti legionella function if applicable the storage is heated above the set ...

Page 16: ...ghest speed of the energy saving pump which is used for example during the flushing or manual operation Show signal Represents the set pump signal in a graphic and text overview Speed control If the speed control is activated itSBMC offers the possibility through a special internal electronic system to change the speed of pumps depending on the process This function should only be activated by a t...

Page 17: ...the display Pressing the esc key takes you back to the previous value so you can look at the selected setting again or adjust it if desired Pressing esc more than once takes you back to the selection mode thus cancelling the commissioning help see Commissioning help on page 11 May only be started by a specialist during commissioning Observe the explanations for the individual parameters in these i...

Page 18: ... 31 means a setting of 20 displayed T 10K actual T 8K 20 correction value Daylight saving time If this function is activated the controller automatically changes to winter time or summer time DST Daylight Savings Time 8 Menu Lock Secure the controller against unintentional changing and compromise of basic functions The menus listed below remain completely accessible despite the menu lock being act...

Page 19: ...ings should be optimized if necessary Performing maintenance l Check the date and time see Time Date on page 17 l Assess check plausibility of statistics see Serve for function control and long term monitoring of the system on page 12 l Check the error memory see Error messages on page 12 l Verify check plausibility of the current measurement values see Measurement values on page 11 l Check the sw...

Page 20: ...m ation cannot be excluded Subject as a basic principle to errors and technical changes Date and time of installation Name of installation company Space for notes Your specialist dealer Manufacturer SOREL GmbH Mikroelektronik Reme Str 12 D 58300 Wetter Ruhr 49 0 2335 682 77 0 49 0 2335 682 77 10 info sorel de www sorel de Version 02 06 2017 20 ...

Reviews: