JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
151
6.4.3
How to connect the pulse source.
The present firmware require that the external pulse source is applied to specific inputs.
These inputs differ from motor family to motor family.
Other input options are under development.
The external source must be connected to the following inputs:
Notice that the Multifunction port pins mentioned above only operate at 5V lev-
els and it is destructive if voltages outside the voltage range 0 to 5V is applied.
6.4.4
Single ended signals
If the external encoder signals are only available as single ended and with voltage levels
up to CVO (typical 24V) it is possible to use IO2+3 as inputs.
To make this change, a small RxP program is required in addition to the settings in
, page 150 Signal formats supported:
Continued next page
Quadrature format
I/O terminal
Pulse/direction format
I/O terminal
Channel A
A1+
and
A1-
Pulse
A1+
and
A1-
Channel B
B1+
and
B1-
Direction
B1+
and
B1-
!