JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
53
2.9
LED indicators basic motor
2.9.1
LED’s - description for products without Ethernet or CANopen.
This description covers all MIS motors with basic configuration without any Ethernet or
CANopen such as MISxxxxxx
Q5
xxxx, MISxxxxxx
Q9
xxxx, MISxxxxxx
FB
xxxx, or
MISxxxxxx
EW
xxxx.
The LED's are used for indicating states and faults.
LED indicator descriptions (default setup)
L1, Red, shows by default the Status bit 15:
Closed loop lead/lag detected. It tells if the mo-
tor is overloaded, which can be caused of too low Running current or too heavy load.
L1 to L3 can be configured to show the status of a almost any single bit from a user de-
fined register. Please see
LED Text Colour Constant off
Constant on
Blinking
L1
Green
Default
Only when user configured Only when user configured
L2
Green
Motor not moving
Motor moving
-
L3
Green
Motor not in position Motor in position
-
ERR
Red
No error
-
Error
PWR
Green
Power is not applied Power is applied to both
motor and module.
Only
MIS17x
and
MIS23x:
The LED will lit red constant-
ly if the supply is too low.
-
TT2344-01GB
Error indicator
Power indicator
Unused but user configurable
Indicator overview
Motor moving
(can also be user configured)
Motor in position
(can also be user configured)
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...