228
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
8.2.109
CUR_SCALE_FACTOR
Description: Closed loop: The slope of the velocity dependent current decrement rate.
See also
8.2.110
KPHASE
The KPHASE parameter is decisive for how far commutation of the motor is offset from
the motor’s actual position. KPHASE is velocity dependent, which means that it has in-
creasing significance as motor velocity increases. The KPHASE parameter is factory cal-
ibrated, but can be adjusted by the user if necessary.
Finding the optimal KPHASE
The optimal KPHASE value is found by running the motor at high speed (2000 RPM) and
observing the “Actual torque” in MacTalk. The actual torque will settle at its minimum
value at the optimal KPHASE. The new KPHASE can be saved in flash and will then be
used automatically after a reset.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
215
CUR_SCALE_
FACTOR
32bit
R/W
1 - 10,000
500
Counts
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
216
KPHASE
32bit
R/W
0-200
-
Counts
N/A