More details of CANopen Theory
Where r is reserved (always 0).
s: is the state of the Heartbeat producer:
Only one communication monitoring service may be activated. This is either Node
Guarding/Life Guarding or Heartbeat. If the Heartbeat Producer Time is configured on
a device, the Heartbeat Protocol begins immediately. If a device starts with a value of the
Heartbeat Producer Time different from 0, the Heartbeat Protocol starts with the state
transition from Initialising to Pre-operational. In this case the Bootup Message is regarded
as the first heartbeat message. If the Heartbeat producer time is not 0, the heartbeat pro-
tocol is used.
In the MIS motors (or SMC66/85), none of the error control mechanisms is enabled
when the modules are started up, because if there is any fault in the system it is impos-
sible to contact the module. After the module has started up and there is communication
between the master and the slave, activate the required error control mechanism in the
object Dictionary. See
DS301 specified Communications objects
s
NMT state
0
Boot up
4
Stopped
5
Operational
7
Pre-operational
TT1084GB
Request
Heartbeat
producer time
Request
Indication
Heartbeat Event
COB-ID = 700h + Node-ID
Indication
7
r
6....0
s
7
r
6....0
s
Heartbeat
consumer time
Heartbeat
consumer time
Heartbeat producer
Heartbeat consumer
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...