232
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
8.2.122
EX_CYCLIC_SETUP
The actual cyclic setup from the Ethernet module.
Settings from the Ethernet module to setup the cycle period and how many percent the
sync-pulse must be offset. These settings can be changed with the specific Ethernet pro-
tocol, but not directly in this register. This is read only.
Bit 0-15: Cycle period (
μ
s)
Bit 16-31: Sync0 offset in percent.
8.2.123
EX_CRC_ERR
CRC error counter of the internal communication between controller and Ethernet
module.
8.2.124
V_HOME_CRAWL
In Zero Search type 2, the “crawl” velocity is V_HOME/64 by default.
If register 242:V_HOME_CRAWL is !=0, a user defined velocity is used – independent
of V_HOME. Please note that overshoot can occur if this velocity is set too high.
8.2.125
V_HOME_TIMEOUT
In all Zero Search modes, the time out is by default 60 s. This delay can changed by writ-
ing a value different from 0 to this register. The unit is milliseconds.
If 0, the Zero Search time out is 60000 ms. Else the value in this register is used.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
239
EX_CYCLIC_SETUP
32bit
R/W
-
0
Special
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
241
EX_CRC_ERR
32bit
R/W
0-2
32
-1
0
Counts
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
242
V_HOME_CRAWL
32bit
R/W
0-300000
(0-3000 RPM)
0
0.01 RPM
Zero search crawl
velocity
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
243
V_HOME_TIMEOUT
32bit
R/W
0-2
32
-1
0
ms
Zero search time-
out
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...