JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
141
5.12.2
Configuration via MacTalk.
When using MacTalk for configuration the following parameters are used:
The desired
Turn Table Mode
is selected here at the
tab
Advanced
The working range can be defined here
after selecting the type of turn table
mode.
Minimum is the lowest position possible
to reach and maximum is the highest position
that can be reached. Both in encoder counts.
Both values are refering to the zero
position found during the optional zero search
or alternatively the zero point defined if using
an absolute multiturn encoder.
After the setup is done please remember to save it
in the permanent memory by pressing the
button.
Save in motor
TT2563-01GB