Safe Torque Off without using MacTalk
If MacTalk is not used for monitoring the status of the STO function it must be done as
follows:
The motor contains a number of registers which can be accessed from various protocols
depending on which options the motor has.
Protocols available are for example Ethernet (EthernetIP, PROFINET etc.) and CAN-
open, Modbus or the MacTalk protocol.
The status of the STO function is also available using above protocols.
Each field in MacTalk described earlier in this chapter can be monitored/read from a reg-
ister in the motor.
The registers that are relevant for the STO function are:
R25
STATUS_BITS
Status bits related to the STO function.
Note that other bits for many other functions in the motor
are also represented in this register.
- Bit 23: Input status for the STOA input.
Reading “0” means that the input is inactive
(no voltage applied).
- Bit 24: Input status for the STOB input.
Reading “0” means that the input is inactive
(no voltage applied).
See also:
R35
ERROR_BITS
Error bits related to the STO function.
Note that other bits for many other functions in the motor
are also represented in this register.
- Bit
27: STO_ALARM.
Will be set if there is an internal hardware defect in
the STO circuitry.
Important
The STO_ALARM will only be set if the STO self-di-
agnostic circuit has detected an internal error.
In this case, the motor must be returned the manu-
facturer (JVL) for repair.
- Bit 29: STO - This bit will be set if one of the 2 STO inputs
are off (not applied an voltage). Also STO is set if the
STO_ACTION_ERROR bit is set.
See also:
Option
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...