38
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
2.8.2
MISxxxxxx
Q5
xxxx connector description.
The MIS motors offers robust M12 connectors which makes it ideal for automation ap-
plications. The M12 connectors offer solid mechanical protection and are easy operate.
Following scheme gives the relevant information about each connector and the pins, wire
colours and a short description of the signals available.
The connector layout:
(Continued next page)
“PWR” (CN1) - Power input. M12 - 5pin male connector
Signal name
Description
Pin no.
JVL Cable
WI1000-
M12F5T
xx
N
Isolation
group
P+
Main 7-72VDC. Connect with pin 2 *
1
Brown
1
P+
Main 7-72VDC. Connect with pin 1 *
2
White
1
P-
Main supply ground. Connect with pin 5 *
3
Blue
1
CVI
Control and user output 7-28VDC.
DO NOT connect >30V to this terminal!
4
Black
1
P-
Main supply ground. Connect with pin 3 *
5
Grey
1
* Note: P+ and P- are each available at 2 terminals. Make sure that both terminals are connected in order
to split the supply current in 2 terminals and thereby avoid an overload of the connector.
TT2332-01GB.cdr
PWR (CN1)
Power input
CN2
RS485 IN/OUT
CN3
RS485 + I/O
CN4
RS485 + I/O + Backup(optional)
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...