JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
223
8.2.97
Fbus_Node_Id
Description: The node id on the CANopen interface.
8.2.98
Fbus_Baud
Description: The baudrate used on the CANopen interface (optional).
0: 1000 kbit/s
1: 800 kbit/s (unsupported)
2: 500 kbit/s
3: 250 kbit/s
4: 125 kbit/s
5: 100 kbit/s
6: 50 kbit/s
7: 20 kbit/s
8: 10 kbit/s
8.2.99
Module Type
Description: Tells which type of module is connected to the internal 1Mbit/s Modbus channel.
0=
No module
0x34 = EthernetIP
0x35 = EtherCAT
0x36 = PowerLink
0x37 = Profinet
0x38 = Modbus/TCP
8.2.100
Ext_Encoder
Description: This register counts the external encoder input at the multifunction I/O.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
166
FBUS_NODE_ID
32bit
R/W
1-127
5
-
CANopen Node ID
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
167
FBUS_BAUD
32bit
R/W
0-8
2
-
Fieldbus -
Baud Rate
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
168
MODULE_TYPE
32bit
R
(dedicated tab in
MacTalk when
module is present)
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
170
EXT_ENCODER
32bit
R/W
(-2
31
)-(2
31
-1)
-
Counts
External Encoder
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...