JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
209
8.2.56
SSI_SETUP1
* Number of data bits. Clock frequency, Disable interrupts when Reading SSI
Description:
SSI encoder interface setup bits:
Bit 0-4:
Number of data bits in each SSI transfer
Bit 5-7:
Number of samples for each SSI position reading
Bit 8-15:
SSI clock frequency in units of 10 kHz
Bit 16-28: Max. sample deviation between each sample
Bit 29-31: Read retries
See also:
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
107
SSI_Setup1
32bit
R/W
32Bit
25bit, 100kHz
frequency pre-
pare time
= 100µs
*
Number of data bits
SSI Clock
Frequency
Wait time
Max. sample deviation
Number of samples
Read retries