188
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Reg
Name
Size Access Range
Default Unit
Description
MacTalk
name
244
TEMP_LIMITS
32bit R
0
Special
The
actual
temperature
limits
in
the
motor:
Bit
0
‐
15:
Warning
limit
(unit:
degC)
Bit
16
‐
31:
Error
limit
(unit:
°C)
N/A
245
CL_CATCH_UP
32bit R/W
‐
0
Special
Bit
0
‐
7:
Allowable
overspeed
in
percent
(0
‐
100)
Bit
8
‐
31:
Follow
error
limit
before
overspeed
is
used.
Allowable
overspeed
Follow
error
before
overspeed
246
TEMP_HIGHRES
32bit R
‐
°C/
1000
Like
register
26
but
the
measured
temperature
is
in
full
resolution
and
presented
in
degree
celcius
x
1000.
Temperature
252
LOWBUSCVI_CNT
32bit R/W
10
Counts
Number
of
times
in
a
row
the
voltage
can
be
too
low
before
error
is
set.
Time
between
each
measurement
=
100
us.
N/A
253
V_ENCODER
32bit R
‐
300,000
‐
300,000
‐
0.01
RPM
The
actual
internal
encoder
velocity.
Internal
encoder
velocity
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...