JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
227
8.2.106
TICKS
Description:
Increments at a fixed rate of 1 count per millisecond. Starts at zero when CVI has
been applied.
8.2.107
CUR_SCALE_MAX
Description:
Closed loop: Max running current in closed loop with "Current control" enabled. 2047
= 100 % of RUN_CURRENT.
8.2.108
CUR_SCALE_MIN
Description: Closed loop: Minimum running current in closed loop with "Current control" enabled.
2047 = 100 % of RUN_CURRENT.
See also
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
202
TICKS
32bit
R/W
0 - (2
32
-1)
0
ms
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
212
CUR_SCALE_MAX
32bit
R/W
0 - 2047
2047
Counts
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
213
CUR_SCALE_MIN
32bit
R
0 - 2047
1
Counts
N/A