234
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
8.2.129
LOWBUSCVI_CNT
Number of times in a row the voltage can be too low before error is set. Time between
each measurement = 50 us.
For motors with serial numbers <173000 this also sets the time before start saving of
the internal Event log. From serial number >173000 the Event log is saved continuously,
every 1 seconds.
8.2.130
V_ENCODER
The actual velocity measured from the internal (H2/H4) encoder.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
252
LOWBUSCVI_CNT
32bit
R/W
-
10
Counts
N/A
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
253
V_ENCODER
32bit
R
-3,000.00 -
3,000.00
-
0.01 RPM
Internal encoder
velocity