248
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
Graphic programming command reference
9.7.7
Move (Absolute)
Icon:
Dialogue:
Function:
Moves to an absolute, non-relative position. The position is given in encoder
counts and can either be entered directly, or can be taken from one of three
memory registers in the user memory area. For further information on using
these memory registers, refer to the sections on the ‘Save position’ and ‘Set
position’ commands.
Note that if you specify a velocity, motor register no. 5 (V_SOLL) will be
overwritten with this velocity value. Also, if you specify an acceleration, motor
register no. 6 (A_SOLL) will be overwritten with the acceleration value
specified.
If the ‘Wait for in position’ option is checked, the program will wait until the
motor has finished the movement before proceeding to the next program line.
If this option is not checked, the program will start the movement, then
immediately start executing the next command. The motor will finish the
movement on its own, unless given other instructions by the program.
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...