After this program has been executed, the external source must be connected to the fol-
lowing inputs:
Please note that the MIS motor family offers different connector configurations.
For specific details about at which connectors the I/O terminals are available please con-
sult: -
Connector overview for the MIS motors
6.4.5
General considerations concerning cabling.
It is strongly recommended that shielded cable is always used when connecting the ex-
ternal pulse source to the pulse input to ensure that no noise from the surroundings af-
fect the quality of the signal and worst case cause the motor movement to get affected.
Also a good, solid ground wire between the motor and the source is recommended since
any differences in the potential between the pulse source and the motor can affect the
motor movement.
General guidelines concerning the I/O’s are given in the following chapters:
Quadrature format
I/O terminal
Pulse/direction format
I/O terminal
Channel A
IO2
Pulse
IO2
Channel B
IO3
Direction
IO3