JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
13
2.1.3
Power Supply - Requirements and Precautions
For optimum performance and lifetime of the MIS motor, it is recommended that a ca-
pacitance of minimum 2200
μ
F is connected to the power supply that supply the P+ ter-
minal. It should be mounted as close as possible to the motor.
Also, it is recommended that minimum 0.75 mm² / AWG22 cable or 2 x 0.5 mm² is used
to connect the power supply to the motor. If the supply voltage drops below 7V, the in-
ternal reset circuitry will reset the driver and an under voltage error is generated. Provi-
sion should therefore be made to ensure that the supply voltage is always maintained at
a minimum of 7V, even in the event of a mains voltage drop.
CVI supply Precautions.
The CVI supply is not critical since the supply current is quite small (<200 mA). Only
make sure that the voltage stay at 24 VDC nominal and do not exceed 30 VDC.
A CVI voltage down to 7 VDC is also possible but a software setup is needed to allow
this. See also
Setup position backup using MacTalk
Warning:
A supply voltage at CVI or P+ higher than 100VDC will cause permanent
damages. A voltage over 30V at the CVI will activate a protection circuit
which shuts down the supply input. In this case CVI need to be disconnected
to reset the protection state.
Fuse dimensioning :
Dimensioning power supply and pre-fuse - MIS23x/MIL23x motors
Dimensioning power supply and pre-fuse - MIS34x/MIL34x motors
Earth
A capacitor in the power supply or
after the output is recommended.
Minimum 2200uF* and rated for 100V.
Prefered is a type with an low
ESR value.
+
TT2538-02GB
This path must in total
be less than 10 meters
otherwise the peak
performance and the
lifetime of the motor
is reduced.
= < 10meters
Power
Supply
7-72VDC
MISxxx Motor
+
P-
(GND)
CVI
(Control circuit supply)
P+
(Main supply)
Fuse
(See text)
* Cap. size : See also table in following chapter
Do not place any components
in this path such as filter inductors,
diodes or resistors. Place any
components before the capacitor.
!
NB: Remember to connect CVI
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...