3.4.16
STO Technical Data
NOTICE : The STO signal must be SELV or PELV supplied.
European directives
Machinery Directive (2006/42/EC)
EN ISO 13849-1/2
EN IEC 62061
EN IEC 61800-5-2
EMC Directive (2014/30/EU)
EN 61000-6-3
EN 61800-3
Low Voltage Directive (2014/35/EU)
EN 61800-5-1
Safety standards
Safety of Machinery
EN ISO 13849-1/2, IEC 62061,
IEC 60204-1
Functional Safety
IEC 61508-1/2, IEC 61800-5-2
Safety function
IEC 61800-5-2
IEC 60204-1
Safe Torque Off
(STO)
Stop
Category 0
Safety performance
ISO 13849-1
Category
Cat 3
Diagnostic Coverage
DCavg: 98,5 % (Medium)
Mean Time to Dangerous Failure
(per channel)
MTTFd: 100 years (High)
PFHd
4,29e-8/h
Performance Level
PLe
IEC 61508 / IEC 62061 / IEC61800-5-2
Safety Integrity Level
SIL 3, SIL CL3
Systematic capability
(systematic integrity level)
SIL 3
Probability of Dangerous Failure
per Hour
PFHd: 1,38e-10/h
(High Demand Mode)
Diagnostic Coverage
DC: 96 %
Safe Failure Fraction
SFF: 96 %
Common Cause Failure Factor
CCF 5 %
Hardware Fault Tolerance
HFT: 1 (1oo2)
Proof Test Interval T1
20 Years
Mission time TM
20 Years
Reaction time
Input to output response time
Maximum 8 ms.
Response time (internal fault)
Maximum 200 ms.
Option
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...