The table below describes how various combinations of setup and encoder options will
affect the value of the actual position register/counter (P_IST) after the motor have pow-
ered power up.
* = Activating the absolute position back-up function makes no sense when the -H3 en-
coder option is installed since it will fully take care of tracking the position including
multiturn in case power is not applied to the motor.
Encoder type
Setup in MacTalk
None
-H2
-H3 *
-H4
“P_IST = 0”
0
0
0
0
“Absolute Singleturn
Encoder”
0
0 - 409599
Only single rev.
position restored
Invalid
not available
0 - 409599
Only single rev.
position restored
“Absolute Multiturn
Encoder”
Last stored
value
Last stored value
corrected for the
/- 1/2 rev.
position
Full abs. mult.
turn position
Last stored value
corrected for the
/- 1/2 rev.
position
Only MISxxx---
H2
---