IPE300 series engineering VFD
Basic operation guidelines
-63-
If static autotuning is selected for motor autotuning, there is no need to disconnect the motor from
the load, but the control performance may be impacted as only a part of the motor parameters
have been autotuned. In addition, autotune
can be obtained through calculation.
Motor autotuning can be carried out on the present motor only. If you need to perform autotuning
on the other motor, switch the motor through selecting the switch-over channel of motor 1 and
motor 2 by setting the ones place of
Related parameter list:
Function
code
Name
Description
Default
Channel of running
commands
0: Keypad
1: Terminal
2: Communication
0
Motor parameter
autotuning
0: No operation
1: Rotary autotuning.
Comprehensive motor parameter autotuning. It
is recommended to use rotating autotuning
when high control accuracy is needed.
2:
Static
autotuning
1
(comprehensive
autotuning); static autotuning 1 is used in cases
where the motor cannot be disconnected from
load.
3: Static autotuning 2 (partial autotuning); when
the present motor is motor 1, only
present motor is motor 2, only
0
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
Rated power of AM 1
0.1
–3000.0kW
Model
depended
Rated frequency of AM 1 0.01Hz
(Max. output frequency)
50.00Hz
Rated speed of AM 1
1
–36000rpm
Model
depended
Rated voltage of AM 1 0
–1200V
Model
depended
Rated current of AM 1 0.8
–6000.0A
Model
depended
Summary of Contents for IPE300 Series
Page 1: ...IPE300 Series Engineering VFD...
Page 3: ......
Page 383: ...6 6 0 0 1 0 0 8 1 2 202106 V1 0...