IPE300 series engineering VFD
Function parameter list
-216-
Function
code
Name
Description
Default Modify
by setting the proportional coefficient and integral
time of speed regulator. Increasing proportional
gain or reducing integral time can accelerate
dynamic response of speed loop; however, if the
proportional gain is too large or integral time is
too small, system oscillation and overshoot may
occur; if proportional gain is too small, stable
oscillation or speed offset may occur.
PI parameters have a close relationship with the
inertia of the system. Adjust PI parameters
depending on different loads to meet various
demands.
setting range: 0.0
–200.0
setting range: 0.000
–10.000s
setting range: 0.00Hz
setting range: 0.0
–200.0
setting range: 0.000
–10.000s
output frequency)
P23.06
Speed-loop
output filter
0
–8 (corresponding to 0–2
8
/10ms)
0
○
P23.07
Electromotive
slip
compensation
coefficient of
vector control
Slip compensation coefficient is used to adjust
the slip frequency of the vector control and
improve the speed control accuracy of the
system. Adjusting the parameter properly can
control the speed steady-state error.
Setting range: 50
–200%
100%
○
P23.08
Braking slip
compensation
coefficient of
vector control
100%
○
P23.09
Current-loop
proportional
coefficient P
Note:
1. These two parameters are used to adjust PI
parameters of current loop; it affects dynamic
response speed and control precision of the
system directly. The default value needs no
adjustment under common conditions;
2. Applicable to SVC mode 0 (P00.00=0), SVC
mode 1 (P00.00=1), and closed-loop vector
control mode (P00.00=3)
Setting range: 0
–65535
1000
○
P23.10
Current-loop
integral
coefficient I
1000
○