IPE300 series engineering VFD
Extension card
-317-
Indicator definition:
Indicator
Definition
Function
LED1
Status indicator
This indicator is on when the extension card is establishing a
connection with the control board;
it blinks periodically after the extension card is properly
connected to the control board (the period is 1s, on for 0.5s,
and off for the other 0.5s);
and it is off when the extension card is disconnected from
the control board.
LED2
Power indicator
This indicator is on after the control board feeds power to the
PG card.
LED3
Disconnection
indicator
This indicator is off when A1 and B1 of the encoder are
disconnected; it blinks when C1 and D1 of the encoder are
disconnected; and it is on when the encoder signals are
normal.
EC-PG502 terminal function description:
Signal
Port
Description
PE
Grounding terminal
It is connected to the ground for enhancing the
anti-interference performance.
PWR
Encoder power
Voltage: 5V ± 5%
Max. output current: 150mA
GND
A1+
Encoder interface
1. Supporting Sin/Cos encoders (with CD signal or
without CD signal)
2. SINA/SINB/SINC/SIND 0.6
–1.2Vpp; SINR
0.2
–0.85Vpp
3. Max. frequency response of A/B signals: 200 kHz
Max. frequency response of C/D signals: 1 kHz
A1-
B1+
B1-
R1+
R1-
C1+
C1-
D1+
D1-
A2+
Pulse setting
1. Differential input of 5 V
2. Response frequency: 200 kHz
A2-
B2+
B2-
Z2+
Z2-