IPE300 series engineering VFD
Function parameter list
-196-
Function
code
Name
Description
Default
Modify
Hundreds place: Motor number
0: Motor 1
1: Motor 2
P17.41
Electromotive
torque upper limit
0.0%
–300.0% (of the motor rated current)
180.0%
●
P17.42
Braking torque
upper limit
0.0%
–300.0% (of the motor rated current)
180.0%
●
P17.43
Forward rotation
upper-limit
frequency in
torque control
0.00
50.00Hz
●
P17.44
Reverse rotation
upper-limit
frequency in
torque control
0.00
50.00Hz
●
P17.45
Inertia
compensation
torque
-100.0%
–100.0%
0.0%
●
P17.46
Friction
compensation
torque
-100.0%
–100.0%
0.0%
●
P17.47
Motor pole pairs 0
–65535
0
●
P17.48
VFD overload
count value
0
–65535
0
●
P17.49
Frequency set by
A source
0.00
0.00Hz
●
P17.50
Frequency set by
B source
0.00
0.00Hz
●
P17.51
PID proportional
output
-100.0%
–100.0%
0.00%
●
P17.52
PID integral
output
-100.0%
–100.0%
0.00%
●
P17.53
PID differential
output
-100.0%
–100.0%
0.00%
●
P17.54
Present
proportional gain
0
–100.0
0.00
●