IPE300 series engineering VFD
Extension card
-322-
A.8.3 Resolver PG card (EC-PG504-00)
PE
AO+
BO+
ZO+
EX+
SI+
CO+
A2+
B2+
Z2+
PWR
PGND
AO-
BO-
ZO-
EX-
SI-
CO-
A2-
B2-
Z2-
PGND
Indicator definition:
Indicator
Definition
Function
LED1
Status indicator
This indicator is on when the extension card is
establishing a connection with the control board;
it blinks periodically after the extension card is properly
connected to the control board (the period is 1s, on for
0.5s, and off for the other 0.5s);
and it is off when the extension card is disconnected from
the control board.
LED2
Disconnection
indicator
This indicator is off when the encoder is disconnected; it is
on when the encoder signals are normal; and it blinks
when the encoder signals are not stable.
LED3
Power indicator
This indicator is on after the control board feeds power to
the PG card.
EC-PG504-00 can be used in combination with a resolver of excitation voltage 7 Vrms. It is
user-friendly, adopting spring cage terminals.
EC-PG504-00 terminal functions:
Signal
Port
Description
PE
Grounding terminal
It is connected to the ground for enhancing the
anti-interference performance.
PWR
Output power supply
Voltage 5V±5%
GND
SI+
Encoder signal input
Recommended resolver transformation ratio: 0.5
SI-
CO+
CO-