Chapter 3 Operation
64
2) When I/O2 is Fieldbus type (Type of extension I/O is either of CC/CC2/DV/DV2/PR/EP/EC/PRT)
Type
Port No.
Function
Type
Port No.
Function
000
300
ALM (LED on the front panel)
001
301
RDY (LED on the front panel)
002
302
EMG (LED on the front panel)
003
303
System reservation
004
304
HPS (LED on the front panel)
005
305
006
306
007
307
008
308
009
309
010
310
011
311
012
312
013
313
014
314
Internal
DI
(I/O1)
015
System reservation
Internal
DO
(I/O1)
315
System reservation
External
DI
(I/O1)
016
to
031
General-purpose input
External
DO
(I/O1)
316
to
331
General-purpose output
032
332
7-segment user display digit
033
333
7-segment user display digit
034
334
System reservation
035
335
System reservation
036
336
System reservation
037
337
7-segment display refresh
038
338
7-segment user/system alternate
039
339
7-segment user display specification
040
340
DT0 (7-segment user display bit)
041
341
DT1 (7-segment user display bit)
042
342
DT2 (7-segment user display bit)
043
343
DT3 (7-segment user display bit)
044
344
DT4 (7-segment user display bit)
045
345
DT5 (7-segment user display bit)
046
346
DT6 (7-segment user display bit)
Internal
DI
(I/O1)
047
System reservation
Internal
DO
(I/O1)
347
System reservation
048
Program start
348
Alarm output
049
349
READY output
050
350
Emergency-stop output
051
351
052
352
053
353
054
General-purpose input
354
055
Program number indication (BCD:1
・
BIN:1) *
355
056
Program number indication (BCD:2
・
BIN:2) *
356
057
Program number indication (BCD:4
・
BIN:4) *
357
058
Program number indication (BCD:81
・
BIN:8) *
358
059
Program number indication (BCD:10
・
BIN:16) *
359
060
Program number indication (BCD:20
・
BIN:32) *
360
061
Program number indication (BCD:40
・
BIN:64) *
361
062
362
063
General-purpose input
363
General-purpose output
External
DI
(I/O2)
064
to
295
General-purpose input
External
DO
(I/O2)
364
to
595
General-purpose output
* Switching over between BCD and BID in Program Number Indication should be conducted in IO
Parameter No. 30 Input Function Select 000.
(1:Program start BCD, 2:Program start binary(BIN))
Summary of Contents for MSEL
Page 1: ...MSEL Controller Instruction Manual Fifth Edition ...
Page 2: ......
Page 4: ......
Page 30: ...22 ...
Page 44: ...Chapter 1 Specifications Check 36 ...
Page 102: ...Chapter 4 Home Return Absolute Reset 94 ...
Page 232: ......
Page 233: ......