Chapter 6
Troubleshooting
175
In the panel window, the error numbers follow E in the display.
Error No.
Error name
Description, action, etc.
C02
Executable program count over
error
Execution requests were received for programs exceeding
the number that can be executed simultaneously.
C03
Non-registered program
specification error
The specified program is not registered.
C04
Program entry point non-detection
error
A request was made to execute a program number for
which no program steps are registered.
C05
Program first-step BGSR error
The program specified for execution starts with BGSR.
C06
Executable step non-detection
error
The program specified for execution does not contain
executable program steps.
C07
Subroutine non-definition error
The subroutine specified for call is not defined.
C08
Subroutine duplicate-definition
error
The same subroutine number is defined at multiple
locations.
C0A
Tag duplicate-definition error
The same tag number is defined at multiple locations.
C0B
Tag non-definition error
The tag specified as the jump destination of a GOTO
statement is not defined.
C0C DW/IF/IS/SL pair-end mismatch
error
The branching command syntax is invalid.
Correspondence with the last appearing branching
command is invalid when EDIF, EDDO or EDSL is used.
Check the correspondence between IF/IS command and
EDIF, DO command and EDDO or SLCT command and
EDSL
C0D DW/IF/IS/SL no pair-end error
EDIF, EDDO or EDSL is not found. Check the
correspondence between IF/IS command and EDIF, DO
command and EDDO or SLCT command and EDSL.
C0E
BGSR no pair-end error
There is no EDSR for BGSR, or no BGSR for EDSR.
Check the correspondence between BGSR and EDSR.
C0F
DO/IF/IS over-nesting error
The number of nests in a DO or IF/IS command exceeds
the limit value. Check for excessive nesting or branching
out of or into the syntax using a GOTO command.
C10
SLCT over-nesting error
The number of nests in a SLCT command exceeds the
limit value. Check for excessive nesting or branching out
of or into the syntax using a GOTO command.
C11
Subroutine over-nesting error
The number of nests in a subroutine exceeds the limit
value. Check for excessive nesting or branching out of or
into the syntax using a GOTO command.
C12
DO/IF/IS under-nesting error
The EDIF or EDDO position is invalid. Check the
correspondence between IF/IS command and EDIF or DO
command and EDDO, or branching out of or into the
syntax using a GOTO command.
C13
SLCT under-nesting error
The EDSL position is invalid. Check the correspondence
between SLCT and EDSR, or branching out of or into the
syntax using a GOTO command.
C14
Subroutine under-nesting error
The EDSR position is invalid. Check the correspondence
between BGSR and EDSR, or branching out of or into the
syntax using a GOTO command.
C15
SLCT next-step command code
error
The program step next to SLCT must be WHEQ, WHNE,
WHGT, WHGE, WHLT, WHLE, WSEQ, WSNE, OTHE or
EDSL.
C16
Create stack failed
Initialization of the input-condition-status storage stuck has
failed.
C17
Expansion-condition code error
Input program step error. The expansion condition code is
invalid.
Operatio
n-can
cellati
on l
evel
errors
C18
Expansion-condition LD
simultaneous processing over
error
The number of LDs processed simultaneously exceeds
the limit value.