Chapter 5 I/O Parameter
107
I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
274 (For extention)
0
275 (For extention)
0
276 (For extention)
0
277 (For extention)
0
278 (For extention)
0
279 (For extention)
0
280 (For extention)
0
281 (For extention)
0
282 (For extention)
0
283
Physical input port number to
input function selection 000
16
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 30, “Input function selection 000”.
* If a negative value is set, the function will be assigned to
input port No. 0.
284
Physical input port number to
input function selection 001
17
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 31, “Input function selection 001”.
* If a negative value is set, the function will be assigned to
input port No. 1.
285
Physical input port number to
input function selection 002
18
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 32, “Input function selection 002”.
* If a negative value is set, the function will be assigned to
input port No. 2.
286
Physical input port number to
input function selection 003
19
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 33, “Input function selection 003”.
* If a negative value is set, the function will be assigned to
input port No. 3.
287
Physical input port number to
input function selection 004
20
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 34, “Input function selection 004”.
* If a negative value is set, the function will be assigned to
input port No. 4.
288
Physical input port number to
input function selection 005
21
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 35, “Input function selection 005”.
* If a negative value is set, the function will be assigned to
input port No. 5.
289
Physical input port number to
input function selection 006
22
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 36, “Input function selection 006”.
* If a negative value is set, the function will be assigned to
input port No. 6.
290
Physical input port number to
input function selection 007
23
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 37, “Input function selection 007”.
* If a negative value is set, the function will be assigned to
input port No. 7.
* If “Program number specified for program start” has been
specified for input function selection 007, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
291
Physical input port number to
input function selection 008
24
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 38, “Input function selection 008”.
* If a negative value is set, the function will be assigned to
input port No. 8.
* If “Program number specified for program start” has been
specified for input function selection 008, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
292
Physical input port number to
input function selection 009
25
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 39, “Input function selection 009”.
* If a negative value is set, the function will be assigned to
input port No. 9.
* If “Program number specified for program start” has been
specified for input function selection 009, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
293
Physical input port number to
input function selection 010
26
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 40, “Input function selection 010”.
* If a negative value is set, the function will be assigned to
input port No. 10.
* If “Program number specified for program start” has been
specified for input function selection 010, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
Summary of Contents for MSEL
Page 1: ...MSEL Controller Instruction Manual Fifth Edition ...
Page 2: ......
Page 4: ......
Page 30: ...22 ...
Page 44: ...Chapter 1 Specifications Check 36 ...
Page 102: ...Chapter 4 Home Return Absolute Reset 94 ...
Page 232: ......
Page 233: ......