Chapter 6
Troubleshooting
187
In the panel window, the error numbers follow E in the display.
Error No.
Error name
Description, action, etc.
E01
DMA address error
DMA transfer error
E02
SCIF send-buffer overflow error
The SCIF send buffer overflowed.
E03
SCI send-buffer overflow error
The SCI send buffer overflowed.
E04
SCIF receive-buffer overflow error The SCIF receive buffer overflowed. Excessive data was
received from outside.
E05
SCI receive-buffer overflow error The SCI receive buffer overflowed. Excessive data was
received from the slave.
E06
Receive timeout error
(Slave communication)
Response from the slave cannot be recognized.
E07
SCI overrun error
(Slave communication)
Communication failure. Check for noise, circuit failure and
slave card.
E08
SCI framing error
(Slave communication)
Communication failure. Check for noise, shorting, circuit
failure and slave card.
E09
SCI parity error
(Slave communication)
Communication failure. Check for noise, shorting, circuit
failure and slave card.
E0A
SCI CRC error
(Slave communication)
The CRC in the message is invalid.
E10
SCIF communication mode error The communication mode is invalid.
E11
SCI communication mode error
The communication mode is invalid.
E12
SIO-bridge SCIF send-queue
overflow error
The send queue overflowed
E13
SIO-bridge SCI send-queue
overflow error
The send queue overflowed
E14
SCI receive-data-register full wait
timeout error
Communication failure. Check for noise, shorting, circuit
failure and slave card.
E15
SCI overrun error
Communication failure. Check for noise, shorting, circuit
failure and slave card.
E16
Program end confirmation timeout
error
The program cannot be ended.
E17
I/O-processing-program start logic
error
The I/O-processing-program start logic is invalid.
E18
Task ID error
The task ID is invalid.
E19
WAIT factor error
The WAIT factor is invalid.
E1A
WAIT logic error
The WAIT logic is invalid.
E1B
Position-data valid address error Position-data valid address is not set.
E1C
Source data error
The source data is invalid.
E1D
Unaffected output number error
The unaffected output number is invalid. A value other
than an output port number (“0” is acceptable) may be
input in I/O parameter Nos. 70 to 73.
E1E
Zone parameter error
A value other than an output port/global flag number (“0” is
acceptable) or duplicate numbers may be input in
axis-specific parameter Nos. 88, 91, 94 and 97, or the
output number specified as system output in the I/O
parameter for output function selection may be duplicated,
among other reasons. * Cartesian axis only.
E1F
I/O assignment parameter error
A value other than an I/O port number (“-1” is acceptable)
or other than an I/O head port [multiple of 8]
may be input in I/O parameter Nos. 2 to 9, or a value other
than a [multiple of 8] may be input in I/O parameter Nos.
14 to 17.
Cold-st
art lev
el errors
E20
I/O assignment duplication error
I/O assignments are duplicated. Check I/O parameter Nos.
2 to 9 and 14 to 17 and the I/O slot card type (number of
I/Os), etc.
Summary of Contents for MSEL