Chapter 5 I/O Parameter
108
I/O Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
294
Physical input port number to
input function selection 011
27
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 41, “Input function selection 011”.
* If a negative value is set, the function will be assigned to
input port No. 11.
* If “Program number specified for program start” has been
specified for input function selection 011, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
295
Physical input port number to
input function selection 012
28
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 42, “Input function selection 012”.
* If a negative value is set, the function will be assigned to
input port No. 12.
* If “Program number specified for program start” has been
specified for input function selection 012, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
296
Physical input port number to
input function selection 013
29
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 43, “Input function selection 013”.
* If a negative value is set, the function will be assigned to
input port No. 13.
* If “Program number specified for program start” has been
specified for input function selection 013, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
297
Physical input port number to
input function selection 014
30
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 44, “Input function selection 014”.
* If a negative value is set, the function will be assigned to
input port No. 14.
* If “Program number specified for program start” has been
specified for input function selection 014, specify in this
parameter an input port number whose LSB contains the
program number specified for program start.
298
Physical input port number to
input function selection 015
31
-1 ~ 299
Specify the port number to be assigned to the function of I/O
Parameter No. 45, “Input function selection 015”.
* If a negative value is set, the function will be assigned to
input port No. 15.
299
Physical output port number to
output function selection 300
316
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 46, “Output function selection 300”.
* If 0 is set, the function will be assigned to output port No.
300.
300
Physical output port number to
output function selection 301
317
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 47, “Output function selection 301”.
* If 0 is set, the function will be assigned to output port No.
301.
301
Physical output port number to
output function selection 302
318
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 48, “Output function selection 302”.
* If 0 is set, the function will be assigned to output port No.
302.
302
Physical output port number to
output function selection 303
319
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 49, “Output function selection 303”.
* If 0 is set, the function will be assigned to output port No.
303.
303
Physical output port number to
output function selection 304
320
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 50, “Output function selection 304”.
* If 0 is set, the function will be assigned to output port No.
304.
304
Physical output port number to
output function selection 305
321
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 51, “Output function selection 305”.
* If 0 is set, the function will be assigned to output port No.
305.
305
Physical output port number to
output function selection 306
322
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 52, “Output function selection 306”.
* If 0 is set, the function will be assigned to output port No.
306.
306
Physical output port number to
output function selection 307
323
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 53, “Output function selection 307”.
* If 0 is set, the function will be assigned to output port No.
307.
307
Physical output port number to
output function selection 308
324
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 54, “Output function selection 308”.
* If 0 is set, the function will be assigned to output port No.
308.
308
Physical output port number to
output function selection 309
325
0 ~ 599
Specify the port number to be assigned to the function of I/O
Parameter No. 55, “Output function selection 309”.
* If 0 is set, the function will be assigned to output port No.
309.
Summary of Contents for MSEL
Page 1: ...MSEL Controller Instruction Manual Fifth Edition ...
Page 2: ......
Page 4: ......
Page 30: ...22 ...
Page 44: ...Chapter 1 Specifications Check 36 ...
Page 102: ...Chapter 4 Home Return Absolute Reset 94 ...
Page 232: ......