Chapter 1 Specifications Check
31
1.4.2 Extension I/O
For extension I/O, selection can be made from PIO (NPN or PNP) and six types of fieldbus
(CC-Link, DeviceNet, FROFIBUS-DP, EtherNet/IP, EtherCAT or PROFINET-IO) to be equipped
with.
[1] PIO Interfaces
Input
Output
Input Voltage
24V DC ±10%
Load Voltage
24V DC ±10%
Input Current
4mA / 1 Circuit
ON
Min. 18V DC
ON/OFF
Voltage
OFF
Max. 6V DC
Load Current
50mA / 1 Circuit
S
pecificatio
Insulation Type
Photocoupler Insulation Insulation Type
Photocoupler Insulation
NPN
PNP
NPN type
PNP type
Caution:
If a non-contact circuit is connected externally, malfunction may result from
leakage current. Use a circuit in which leakage current in a OFF state does not
exceed 1mA.
At the default settings, the system recognizes the ON/OFF durations of input
signals if they are continuous approx. 4 msec or longer. The ON/OFF duration
settings can also be changed using I/O parameter No. 20 (input filtering
frequency).
MSEL
5.6kΩ
Input Terminal
logic
circuit
Input
Terminal
5.6kΩ
logic
circuit
Output
Terminal
15Ω
Load
Output
Terminal
15Ω
Load
MSEL
External
Power
Source
24V DC
±10%
External
Power
Source
24V DC
±10%
External
Power
Source
24V DC
±10%
External
Power
Source
24V DC
±10%
MSEL
MSEL
In
te
rn
al ci
rcu
it
In
te
rn
al ci
rcu
it
In
te
rn
al ci
rcu
it
In
te
rn
al ci
rcu
it