
Chapter 5 I/O Parameter
141
[Shortcut Control for Multi-Rotation Type Rotary Actuator]
The shortcut control select can be set enable/disable in each axis parameter No. 67 “Rotary
Movement Axis Shortcut Control Select”. Movement can be performed in one way when the
shortcut select is set enable.
[Example for Operation]
Position No.
Position
1
0
2
90
3
180
4
270
Position data is to be input as
1deg = 1mm. e.g.) 1.2 is treated
as 1.2deg.
The operation will differ when shortcut select is disabled from when it is enabled if movement
is made in the order of positions 1 → 2 → 3 → 4
→ 1.
・
When Disabled
・
When Enabled
Position No.1
Position No.4
Position No.3
Position No.2
Summary of Contents for MSEL
Page 1: ...MSEL Controller Instruction Manual Fifth Edition ...
Page 2: ......
Page 4: ......
Page 30: ...22 ...
Page 44: ...Chapter 1 Specifications Check 36 ...
Page 102: ...Chapter 4 Home Return Absolute Reset 94 ...
Page 232: ......
Page 233: ......