If the vehicle is equipped with the ISG (Idle stop and go) and AMS (Alternator Man
-
agement System) functions, there is a battery sensor instead of the normal ground
cable. Care must be taken not to damage this sensor when handling the main bat
-
tery.
There are two holes in the battery for venting the H2 gas. Because the main battery
is located in the interior, this gas should be passed to the outside of the vehicle. To
do this, stop up the vent hole located near the (+) pole and connect the hose to the
vent hole located near the (-) pole. The gas from the battery is delivered to the out
-
side by means of this system.
Fig. 7-172 SPBGC74_003 Main battery connections
1
Battery sensor
3
Vent hose
2
Earth bolt (2EA)
4
Main battery